Influence of Tilt Angle Guide Valve 60°, 80° & 90° of Work Method Turbin Crossflow Desalination Plant Capacity 1000 Ton/Day
Pengaruh Variasi Sudut Guide Valve 60°, 80° & 90° terhadap Unjuk Kerja Turbin Crossflow pada Desalination Plant Berkapasitas 1000 Ton/Hari
DOI:
https://doi.org/10.21070/ups.3683Keywords:
Generator, TurbinAbstract
Microhydro Power Plants (PLTMH) are one of the plants included in New Renewable Energy (EBT), the use of crossflow type water turbines is suitable for water flows which have other characteristics of low height (head) and flow rates that are not too fast. The potential flow of sea water out of the Desalination Plant has a flow capacity of 0.114 m/s at a Desalination Load Setter load of 70% and a capacity of 0.126 m/s at a Desalination Load Setter load of 80%, with a head of around 1 meter. This research aims to find variations in the load of the Desalination Load Setter which will affect the air flow discharge as well as variations in the opening of the PLTMH guide valve 60°, 80° & 90°.
Downloads
References
J. Sih Setyono, F. Hari Mardiansjah, and M. Febrina Kusumo Astuti, “Potensi Pengembangan Energi Baru dan Energi Terbarukan di Kota Semarang,” Jurnal Riptek, vol. 13, no. 2, pp. 177–186, 2019, [Online]. Available: http://riptek.semarangkota.go.id
B. Ardo, “Perencanaan Pembangkit Listrik Tenaga Mikro Hidro (PLTMH) di Desa Tanjung Raman Talang Air Selepah Kecamatan Pendopo Kabupaten Empat Lawang,” vol. 19, no. 1, p. p-ISSN, 2022.
Purwanto, PEMBANGKIT LISTRIK TENAGA MIKROHIDRO (PLMTH), JAKARTa: LIPI, 2017.
M. Nafi’uddin Amin, “PENGARUH TURUNNYA FLOW BRINE RECIRCULATION PUMP TERHADAP KINERJA DESAL C UNIT 5-7 PLTU SURALAYA,” 2019.
E. Naryono and S. Diniardi, “ANALISA PERENCANAAN DESALINATION PLANT 4167 TON/JAM.”
I. Putu Andrean Wiranata, I. Gusti Ngurah Janardana, and I. Wayan Arta Wijaya, “Rancang Bangun Prototype Pembangkit Listrik Tenaga Mikro Hidro Menggunakan Turbin Cross-Flow,” Jurnal SPEKTRUM, vol. 7, no. 4, pp. 151–160, 2020.
D. A. P. Harwan Ahyadi, “ANALISA RANCANG BANGUN TURBIN CROSS-FLOW SALURAN,” PRESISI, vol 24 No 2, Juli 2022.
G. B. Mahendra and A. Multi, “PERANCANGAN PLTMH MEMANFAATKAN DISCHARGE POMPA BRINE BLOWDOWN PADA PLTGU.”
A. T. Saputra, A. I. Weking, and I. W. Artawijaya, “Eksperimental Pengaruh Variasi Sudut Ulir Pada Turbin Ulir (Archimedean Screw) Pusat Pembangkit Listrik Tenaga Mikro Hidro Dengan Head Rendah,” Majalah Ilmiah Teknologi Elektro, vol. 18, no. 1, p. 83, May 2019, doi: 10.24843/mite.2019.v18i01.p12.
D. Prasetio, M. Agus Sahbana, and D. Dadang Hermawan, “OPTIMASI LP (LOW PRESSURE) AUXILIARY STEAM PADA DESALINATION PLANT UNTUK MENINGKATKAN PRODUKSI STEAM TURBINE PLTGU GRATI,” Journal Mechanical and Manufacture Technology, vol. 2, no. 1, 2021.
M. Wildan, N. Karim, M. Widyartono, A. Chandra Hermawan, and S. I. Haryudo, “Kajian Kemiringan Blade dan Head Turbin Archimedes Screw Terhadap Daya Keluaran Generator AC 1 Phase 3 kW.”
M. F. A. Islam, “Pembuatan dan Pengujian Turbin Air Dengan Sudu Bentuk 1/4 Lingkaran Pada Arah Aliran Undershoot Terhadap Daya dan Efisiensi Turbin,” 2021.
E. Saefudin, T. Kristyadi, M. Rifki, and S. Arifin, “Turbin Screw Untuk Pembangkit Listrik Skala Mikrohidro Ramah Lingkungan,” Jurnal Rekayasa Hijau, no. 3, 2017.
A. A. Salam, “KARAKTERISTIK DAYA DAN EFISIENSI TURBIN ARCHIMEDES SCREW TERHADAP HEAD KONSTAN YANG DIUJI PADA SALURAN TERTUTUP,” 2021.
A. Nugraha, M. N. Ramadhan, A. Syarief, and D. S. Adianto, “ANALISIS KINERJA TURBIN ARCHIMEDES SCREW PADA PEMBANGKIT LISTRIK TENAGA MIKRO HIDRO,” ELEMEN : JURNAL TEKNIK MESIN, vol. 9, no. 1, pp. 48–56, Aug. 2022, doi: 10.34128/je.v9i1.183.
Downloads
Additional Files
Posted
License
Copyright (c) 2024 UMSIDA Preprints Server
This work is licensed under a Creative Commons Attribution 4.0 International License.