Effect of Flat Plate Solar Collector Tilt Angle Against Pressure Drop
Pengaruh Sudut Kemiringan Solar Kolektor Tipe Plat Datar Terhadap Preassure Drop
DOI:
https://doi.org/10.21070/ups.1879Keywords:
Collector, Fluid, TemperatureAbstract
A flat plate solar collector is used to absorb radiant heat energy from a 150 Watt light beam and then forward it to the collector pipe which is fed by water. Variation of the angle of 0⁰ heat received by collector water is 66.4℃ with a pressure difference of -2. Testing using a variation of the lamp flame for 90 minutes obtained data of 44.8 ℃ with a pressure difference of -1. For 4 lamps, a temperature of 60.8℃ is obtained with a pressure difference of -1.5
Downloads
References
R. Subagyo, A. Mursadin, P. Studi, T. Mesin, F. Teknik, and U. Lambung, “Mekanika fluida ii (hmkk431),” 2017.
S. Akmal and N. Za, “Jurnal Teknologi Kimia Unimal Analisa Profil Aliran Fluida Cair dan Pressure Drop pada Pipa L menggunakan Metode Simulasi Computational Fluid Dynamic ( CFD ),” vol. 2, no. November, pp. 53–72, 2019.
H. Susanto and D. Irawan, “PENGARUH JARAK ANTAR PIPA PADA KOLEKTOR TERHADAP PANAS YANG DIHASILKAN SOLAR WATER HEATER ( SWH ),” vol. 6, no. 1, pp. 84–91, 2017.
M. Irsyad and A. E. Salsabillah, “Pengaruh Jarak antar Pipa Absorber terhadap Unjuk Kerja Kolektor Surya PV / T Pelat Datar Menggunakan Metode CFD,” vol. 17, no. 3, pp. 405–412, 2022.
E. A. Handoyo and D. F. Teknik, “Pengaruh Jarak Kaca Ke Plat Terhadap Panas Yang Diterima Suatu Kolektor Surya Plat Datar,” vol. 3, no. 2, pp. 52–56, 2001.
F. T. Industri, “RANCANG BANGUN PEMANAS AIR TENAGA SURYA DENGAN MENGGUNAKAN KOLEKTOR,” 2012.
T. P. Datar, “EXPERIMENTAL STUDY OF THE EFFECT OF ADDITION GLASS WOOL AS INSULATION MATERIAL ON THE PERFORMANCE OF FLAT PLATE TYPE SOLAR,” vol. 5, no. 02, 2022, doi: 10.25299/rem.2022.vol5(02).9982.
M. S. Eff, A. Hendarawan, and N. Rahman, “PENGGUNAAN SOLAR COLLECTOR SEBAGAI PEMANAS AWAL AIR MASUK DAN PEMANAS TAMBAHAN BAWAH HEAT ABSORBER PADA BASIN SOLAR STILL UNTUK MENINGKATKAN EFISIENSI,” vol. 8, no. 2, 2016.
N. Era, D. Jayanti, and A. Fahruddin, “Design A U Manometer With Variations In Tube Diameter And Flow Discharge [ Rancang Bangun Manometer U Dengan Variasi Diameter Tube Dan Debit Aliran ],” pp. 1–8.
“RANCANG BANGUN ALAT UJI HEAD LOSSES DENGAN VARIASI DEBIT DAN JARAK ELBOW 90 O UNTUK SISTEM PERPIPAAN YANG,” vol. 7, no. 1, pp. 32–35, 2018.
Downloads
Additional Files
Posted
License
Copyright (c) 2023 UMSIDA Preprints Server
This work is licensed under a Creative Commons Attribution 4.0 International License.