Comparison of the Effectiveness of K3EDTA and Na2EDTA Anticoagulants on the Stability of Differential Leukocyte Count (DLC) Results Using Manual and Automated Methods Whole Blood Storage
Perbandingan Efektivitas Antikoagulan K3EDTA dan Na2EDTA terhadap Stabilitas Pemeriksaan Differential Leukocyte Count (DLC) dengan Metode Manual dan Otomatis pada Penyimpanan Whole Blood
DOI:
https://doi.org/10.21070/ups.11344Keywords:
Differential Leukocyte Count, Types of Antikoagulant, Whole Blood, Storage Stability, Examination MethodeAbstract
The differential leukocyte count is a hematological test used to determine the percentage of leukocyte types, aiding in clinical diagnosis. Result accuracy is influenced by pre-analytical factors. This study aimed to analyze the effect of storage duration on whole blood samples using K3EDTA and Na2EDTA anticoagulants on differential leukocyte count results obtained via manual and automated methods. This laboratory-based experimental study employed a cross-sectional design using venous blood samples from six respondents, analyzed via peripheral blood smears and a hematology analyzer at various storage intervals. Two-way analysis revealed no significant effect (p>0.05) on lymphocyte and granulocyte parameters. Kruskal–Wallis test results indicated that storage duration and testing method significantly influenced mid-cell parameters (p<0.05), whereas the type of anticoagulant did not (p>0.05). It is concluded that storage duration and testing method affect differential leukocyte count results, while the use of K3EDTA versus Na2EDTA anticoagulants does not yield a significant difference.
Downloads
References
M. Daves et al., “Modern hematology analyzers: beyond the simple blood cells count (with focus on the red blood cells),” J. Lab. Precis. Med., vol. 9, pp. 1–9, 2024, doi: 10.21037/jlpm-23-32.
N. U. Pratama, “Perbedaan hitung jenis leukosit menggunakan sediaan apus darah tepi dengan sediaan apus buffy coat pada penderita leukopenia demam tifoid,” Repository, 2018.
A. Aliviameita and Puspitasari, Modul Praktikum Hematologi 4. 2018.
D. Park et al., “Development of a Novel Flow Cytometry-Based System for White Blood Cell Differential Counts : 10-color LeukoDiff,” Ann Lab Med, vol. 39, pp. 141–149, 2019.
C. Review, O. F. Manual, H. Methods, E. Technologies, and I. N. Hematology, “Comparative Riview Of Manual Hematological Methods And Emerging Technologies In Hematology Diagnostics,” Pakistan J. Med. Caardiological Riview, vol. 5, no. 2, pp. 1598–1616, 2026.
P. Puspitasari, A. Aliviameita, S. D. Y. Wahyudhi, and F. P. Purwanti, “Stabilitas Sampel Darah Terhadap Profil Hematologi Dengan Metode Otomatis,” J. Muhammadiyah Med. Lab. Technol., vol. 5, no. 1, p. 1, 2022, doi: 10.30651/jmlt.v5i1.12667.
P. D. Mankar, K. Hatgaonkar, M. G. Kohale, R. S. Wankhade, and G. R. Bandre, “Enhancing Quality in Hematology Laboratory Testing: A Comprehensive Review of Preanalytical Phase Errors and Prevention Strategies,” J. Appl. Hematol., vol. 15, no. 2, pp. 95–101, 2024, doi: 10.4103/joah.joah_3_24.
A. Arshad, A. Safdar, M. Atif, H. Hussain, M. Waqas, and S. Mahmood, “Effects of Anticoagulants on Blood Cells Morphology and Biochemistry,” Biol. Clin. Sci. Res. J., vol. 2024, no. 1, p. 663, 2024, doi: 10.54112/bcsrj.v2024i1.663.
S. Mannu, “Influence of different methods and anticoagulants on platelet parameter measurement,” vol. 44, no. 5, pp. 255–272, 2020, doi: https://doi.org/10.1515/labmed-2020-0037.
A. Rahmnitarini, Y. Hernaningsih, and Y. N. Indrasari, “The stability of sample storage for complete blood count (CBC) toward the blood cell morphology,” Bali Med. J., vol. 8, no. 2, pp. 391–395, 2019, doi: 10.15562/bmj.v8i2.1369.
P. Kadam, N. Patil, and V. P. Mane, “Study of refrigerated storage of blood at 4°C on automated hematological parameters & morphological changes in peripheral blood smear: A prospective study,” Indian J. Pathol. Oncol., vol. 10, no. 1, pp. 9–14, 2023, doi: 10.18231/j.ijpo.2023.003.
V. C. J. Riba et al., “Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogram,” J. Bras. Patol. e Med. Lab., vol. 56, pp. 1–6, 2020, doi: 10.5935/1676-2444.20200037.
H. Thabet, N. Ghandour, and M. Bakr, “Determination of Blood Age by Morphological Changes of Different White Blood Cells,” Mansoura J. Forensic Med. Clin. Toxicol., vol. 26, no. 2, pp. 113–124, 2018, doi: 10.21608/mjfmct.2018.47197.
A. Purushothaman, P. Meenatchi, and S. Fathima, “Comparison of Manual Versus Automated Data Collection Method for Haematological Parameters,” Biomed. J. Sci. Tech. Res., vol. 15, no. 3, pp. 11372–11376, 2019, doi: 10.26717/bjstr.2019.15.002702.
G. Onofrio, “Full-Field Hemocytometry . Forty Years of Progress Seen Through Clinical and Laboratory Hematology and the International Journal of Laboratory Hematology,” vol. 43, no. March, pp. 7–14, 2021, doi: 10.1111/ijlh.13546.
C. Avram and M. Marusteri, “Normality assessment , few paradigms and use cases,” vol. 30, no. 3, pp. 251–260, 2022, doi: 10.2478/rrlm-2022-0030.
P. Mishra, C. M. Pandey, and U. Singh, “Descriptive Statistics and Normality Tests for Statistical Data,” vol. 22, no. 1, pp. 67–72, 2019, doi: 10.4103/aca.ACA.
M. Bruegel et al., “Multicenter evaluation of the cobas m 511 integrated hematology analyzer,” Int. J. Lab. Hematol., vol. 40, pp. 672–682, 2018, doi: 10.1111/ijlh.12903.
C. Coutaz, A. Mamin, and K. Mintzas, “Evaluation of the Sysmex XQ- 320 three part differential haematology analyser and its flagging capabilities,” J. Clin Lab Anal, vol. 38, pp. 1–12, 2024, doi: 10.1002/jcla.25017.
A. Aliviameita, P. Puspitasari, W. I. Amilya, and I. El Savitra, “Optimization of Whole Blood Specimen Handling for Complete Blood Count ( CBC ) Results and Blood Cell Morphology,” vol. 16, no. 2, pp. 285–296, 2025.
H. Kayadibi, I. A. Acar, and S. Cam, “Stability of complete blood count parameters depends on the storage temperature , storage time , transport position and selected stability criterion,” Scand. J. Clin. Lab. Invest., vol. 0, no. 0, pp. 1–9, 2020, doi: 10.1080/00365513.2020.1783570.
C. Kangwende, F. Ajeneye, E. Nkansah, M. Adelusi, N. Tanwair, and S. Baines, “Evaluating Blood Sample Storage Conditions And How It Can Affect Haematology Interpretation At The PAH,” J. Community Med. Public Heal. Reports, vol. 5, no. 08, pp. 1–7, 2024.
M. M. Bajimaya et al., “Manual differential count and automated differential leukocyte count in normal individuals: a comparative study,” vol. 2, no. 1, pp. 21–24, 2021, doi: https://doi.org/10.3126/jpsn.v2i1.42289.
E. M. Fenu, T. Naal, and E. Palavecino, “Case Report Storage Artifact Masquerading as Yeast : Presenting a Diagnostic Pitfall,” Case Rep. Pathol., vol. 2022, pp. 3–5, 2022, doi: https://doi.org/10.1155/2022/3326214.
D. V. Swami, A. S. K. Keswani, S. L. Gaikwad, D. S. Jadhav, and A. N. Bagate, “Effect of Blood Sample Storage on Sample Stability for CBC and Blood Cell Morphology Analysis,” Res. J. Med. Sci., vol. 19, no. 2, pp. 349–353, 2025, doi: 10.36478/makrjms.2025.2.349.353.
Downloads
Additional Files
Posted
Categories
License
Copyright (c) 2026 UMSIDA Preprints Server

This work is licensed under a Creative Commons Attribution 4.0 International License.