Abstract

Differential leukocyte count (DLC) is a hematological examination affected by preanalytical factors, including storage time and anticoagulant type. This study evaluated the effect of storing whole blood with K₃EDTA and Na₂EDTA on DLC results using manual and automated methods. A cross-sectional laboratory experiment was conducted in April 2026 involving six D4 Medical Laboratory Technology students at Muhammadiyah University of Sidoarjo. Blood samples were analyzed immediately (0 hours) and after 36 and 72 hours of refrigerated storage (2–8°C) using Na₂EDTA and K₃EDTA anticoagulants. DLC parameters included lymphocytes, MID-Cells, and granulocytes. Storage time and anticoagulant type showed no significant effect on all DLC parameters (p > 0.05), whereas the examination method significantly affected MID-Cells (p < 0.05). These findings indicate that both Na₂EDTA and K₃EDTA maintain DLC stability for up to 72 hours under refrigerated conditions, although leukocyte morphological alterations may occur during prolonged storage.

Downloads

Download data is not yet available.

References

Aristoteles and N. Puspitasari, “Perbedaan Hitung Jumlah Leukosit Segera dan Disimpan Selama 6 Jam,” J. Heal. Appl. Sci. Technol., vol. 1, no. 1, pp. 16–20, 2023, doi: 10.52523/jhast.v1i1.4.

D. Y. Wiratma and A. Situmorang, “Tingkat Kualitas Pemantapan Mutu Internal Pra Analitik Pemeriksaan Hematologi,” J. Anal. Lab. Med., vol. 1, no. 1, pp. 24–31, 2016.

U. Sukorini, T. Ratnaningsih, and D. Ikarumi, “The Effect of Excessive Disodium Ethylene Diamine Tetraacetic Acid (Na2EDTA) Anticoagulant Concentration on Leukocytes Profile in Peripheral Blood Examination,” Med. J. Indones., vol. 16, no. 3, pp. 168–175, 2007, doi: 10.13181/mji.v16i3.271.

A. Anggreyani, “Perbandingan Differential Count Jumlah Sel Granulosit dengan Metode Impedansi dan Cara Manual - Repository Universitas Muhammadiyah Semarang.” Accessed: Sep. 21, 2025. [Online]. Available: http://repository.unimus.ac.id/2261/

A. Aliviameita, S. Dilla, Y. Wahyudhi, and F. P. Purwanti, “Stabilitas Sampel Darah Terhadap Profil Hematologi dengan Metode Otomatis,” vol. 1, no. 5, pp. 1–7, 2022.

G. Nugraha, N. A. Ningsih, T. Sulifah, and S. Fitria, “Stabilitas Pemeriksaan Hematologi Rutin pada Sampel Darah yang Didiamkan pada Suhu Ruang Menggunakan Cell-Dyn Ruby,” J. Muhammadiyah Med. Lab. Technol., vol. 4, no. 1, p. 21, 2021, doi: 10.30651/jmlt.v4i1.8255.

G. Bourner et al., “ICSH Guidelines for The Verification and Performance of Automated Cell Counters for Body Fluids,” Int. J. Lab. Hematol., vol. 36, no. 6, pp. 598–612, 2014, doi: 10.1111/ijlh.12196.

A. F. Lestari, S. Hartini, and D. S. Prihandono, “‘Gambaran Jumlah Trombosit pada Penggunaan Antikoagulan Na2EDTA dan K2EDTA,’” J. Kesehat. Tanbusai, vol. 4, no. 3, pp. 3101–3108, 2023.

N. D. K. Sari, G. Nugraha, B. T. Dibiasi, and M. A. Prayoga, “Perbedaan Hasil Pemeriksaan Hematologi yang Segera Dilakukan Pemeriksaan dan yang Ditunda pada Suhu Ruangan dan Refrigerator menggunakan Sysmex XP-300,” Borneo J. Med. Lab. Technol., vol. 4, no. 2, pp. 279–291, 2022.

A. Rahmnitarini, Y. Hernaningsih, and Y. N. Indrasari, “The Stability of Sample Storage for Complete Blood Count (CBC) Toward The Blood Cell Morphology,” Bali Med. J., vol. 8, no. 2, pp. 391–395, 2019, doi: 10.15562/bmj.v8i2.1369.

V. C. J. Riba et al., “Interference of Blood Storage Containing K2EDTA and K3EDTA Anticoagulants in The Automated Analysis of The Hemogram,” J. Bras. Patol. e Med. Lab., vol. 56, Jan. 2020, doi: 10.5935/1676-2444.20200037.

R. Mehmood, R. Khushi, M. Sajjid, and H. Aniqa, “Evaluation of Di-Potassium and Tri-Potassium EDTA Evacuated Tubes for Routine Haematological Testing,” J. Clin. Lab. Anal., no. August 2016, pp. 2–5, 2018, doi: 10.1002/jcla.22188.

N. S. Alam, Nur. I Gusti Putu Agus Ferry Sutrisna, “Pengaruh Waktu Penyimpanan Sampel Darah EDTA pada Suhu Ruangan Terhadap Nilai Trombosit dan Leukosit,” J. MediLab Mandala Waluya, vol. 9, no. 1, 2025.

M. Jaya, Anu. Kakkar, Naveen. John, “Effect of Room Temperature and Refrigerated Storage on Automated Complete Blood Count : A Longitudinal Study,” pp. 57–61, 2022, doi: 10.4103/cjhr.cjhr.

H. Y. Hariyanto. Hermawati, Andyanita Hanif. Prastama, “Perbedaan EDTA Konvensional dan EDTA Vacutainer pada Pemeriksaan Kadar Hemoglobin,” Borneo J. Med. Lab. Technol., pp. 614–620, 2023.

A. P. Aliviameita, Pemeriksaan Hematologi Rutin. Sidoarjo: UMSIDA PRESS, 2024.

A. Aliviameita, P. Puspitasari, W. I. Amilya, and I. El Savitra, “Optimization of Whole Blood Specimen Handling for Complete Blood Count ( CBC ) Results and Blood Cell Morphology,” J. Kesehat., vol. 16, no. 2, pp. 285–296, 2025.

C. Kangwende, F. Ajeneye, E. Nkansah, M. Adelusi, N. Tanwair, and S. Baines, “Evaluating Blood Sample Storage Conditions and How it Can Affect Haematology Interpretation at The PAH,” J. Community Med. Public Heal., vol. 5, no. 08, pp. 1–7, 2024.

A. Astrand et al., “A Comparative Study of Blood Cell Count in Four Automated Hematology Analyzers: An Evaluation of The Impact of Preanalytical Factors,” PLoS One, pp. 1–19, 2024, doi: 10.1371/journal.pone.0301845.

C. Coutaz, A. Mamin, and K. Mintzas, “Evaluation of the Sysmex XQ- 320 Three­Part Differential Haematology Analyser and its Flagging Capabilities,” Journal of Clinical Laboratory Analysis, no. January, pp. 1–12, 2024, doi: 10.1002/jcla.25017.

E. Queen, O. E. Ifeanyi, and O. Kingsley, “The Effect of Storage on Full Blood Count in Different Anticoagulant,” IOSR J. Dent. Med. Sci., vol. 13, no. 9, pp. 128–131, 2014.

E. T. D. A. Kurniasih, “Perbandingan Hasil Hitung Jumlah Sel Darah Spesimen Darah Vena EDTA Menggunakan Metode Manual dan Otomatis,” Borneo J. Med. Lab. Technol., pp. 495–501, 2024.

A. Adewoyin and B. Nwogoh, “Peripheral Blood Film - A Review,” Ann. Ibadan Postgrad. Med., vol. 12, no. 2, pp. 71–79, 2014.

S. M. Wijaya, F. P. Anggraeni, S. Prabandari, and A. N. Sari, “Perbedaan Hasil Pemeriksaan Darah Rutin yang disimpan pada Suhu 4-8 Derajat C ditunda 1 Jam dan 3 Jam,” Pros. Semin. Inf. Kesehat. Nas., pp. 131–139, 2024.

A. Irding, F. Landgren, and E. Aardal, “Dependent EDTA Effect on Leukocyte Differential Count and Morphology Compared to Blood Smear Made by Direct Finger Prick,” Int. J. Lab. Hematol., pp. 826–831, 2025, doi: 10.1111/ijlh.14498.

Posted

2026-07-16